loading

KF08-5YW Oxygen Concentrator

  • Voice Function: Voice Prompts and Wake-up Function
  • Continuous Flow Mode: Continuous oxygen delivery
  • Pulse Flow Mode: Oxygen delivered during inhalation only
  • Home Healthcare Use
  • Ultra-clear LED Display
  • Real-time Data Monitoring
  • Molecular Sieve Filtration
  • KF08-5YW

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
FeatureSpecification

Product name

Oxygen Concentrator

Model

KF08-5YW

Rated voltage and frequency

AC220-240V, 50Hz

Mode of operation

Continuous duty

Rated input power

450VA

Noise level (average)

≤ 60 dB (A) at 5 L/min;

Alarm sound volume

≥ 62 dB(A)

Altitude

It can be used normally in environments below 1828 m above sea level.

It is not recommended for use at altitudes higher than 1828 m. Oxygen flow and concentration will be significantly compromised at altitudes above 1828 m.

Physical and chemical parameters of output oxygen

*The claimed oxygen concentration level (93% ± 3%) (V/V) can be obtained after a certain period of warm-up (approximately 30 min after power-on).

Carbon dioxide content: ≤ 0.01% (V/V)

Carbon monoxide content: ≤ 0.0005% (V/V)

Particle size of solid substance: ≤ 10 μm

Solid substance content: ≤ 0.5 mg/m³

Maximum output pressure

≤ 70 kPa

Flow range

0.6-5 L/min

Flow accuracy

The flow should be ± 10% of the indicated value or ± 200 mL/min at the back pressure of 0 kPa and 7 kPa, whichever is greater.

Low flow alert

There is an alert in sharp beeps when the flow is below 0.6 L/min (when no accessories are connected to the device).

Maximum system allowable pressure

(Pressure protection)

241 ± 24.1 kPa

Flow fluctuation

(at the back pressure of 7 kPa)

< 0.6 L/min

Circuit breaker

F6.3AH250V

Filters

Oxygen outlet filter and compressor inlet filter

Safety system

Oxygen concentration/flow displayCompressor error alarmCompressor high temperature protectionCirculation pressure fault alarmLow oxygen concentration alarmSystem communication fault alarmLow supply voltage alarm Temperature error alarmPower outage alarmNo-breathing alarmLow flow alertLow oxygen concentration alert


IP rating

IP21: solid object ingress protection level 2, water ingress protection level 1

Size

42 (L) *28(W) *55(H)CM

Weight

16.35kg

Operating environment

Temperature: 5℃ ~ 40℃

Relative humidity: ≤80%

Atmospheric pressure: 81kPa-106kPa

Exhaust air temperature

No higher than 75°C

Output oxygen temperature

No higher than 45°C

Note: Under the specified environmental and operational conditions, the temperature in question is considered safe for prolonged oxygen administration to patients via a nasal cannula, posing no risk of burns or thermal damage. Oxygen undergoes rapid cooling as it flows through the catheter and mixes with ambient air. The actual temperature of oxygen perceived within the patient's nasal cavity will not be significantly higher than the ambient temperature.

Electricity

No extended power cord

Main components and structure

The product consists of a filtration system, a compressor, left and right sieve canister assemblies, a circuit control system, a noise reduction system, pulse oxygen delivery system, electronic flow regulation system, intelligent voice system, embedded software (release version No.: ZY004), a humidifier bottle, and connecting tubing.

Placement

No less than 7.5 cm away from a wall, furniture, tapestry or similar object.

Continuous operation time per day

24h

Storage and transportation environment

Temperature: -20℃ ~ 55℃

Relative humidity: ≤93%

Atmospheric pressure: 81kPa-106kPa

Manufacturing date

See the outer packaging

Service life/ Shelf life

5 years

Type BF applied part

Nasal cannula

Indicator Light

State

Indicator LED (diode)

Alert

Red LED

Alarm

Yellow LED

Normal operation

Green LED

Circuit Breaker

686Series

125/250VAC/50VDC F6.3AH250V

When the input current of the oxygen concentrator exceeds the rated current of the circuit breaker, the circuit breaker will be automatically deactivated for protection in case of electric shock, and the oxygen concentrator will stop working. When the user excludes abnormal power supply, just press the button on the top of the circuit breaker, and the circuit breaker can resume working

Accessories

Name

Quantity

Remarks

Instruction manual

1

Standard

Remote controller

1

Optional

Nasal cannula

1

Standard